System sizer

Rough size your system in a minute

This is a starting point, not a final design. Send the result with your question and we’ll check it against your real loads.

What are you powering?
8 kWh a day
1 kWh, lights and a fridge30 kWh, a whole house
1.5 days
Half a day3 days
3,000 watts
500 W10,000 W

Your starting point

Solar array
2.8 kW
7 panels at 400 watts
Battery bank
15 kWh
12 kWh usable
Inverter
4 kW
Continuous, pure sine
System voltage
48 V
Battery bank voltage

Send these numbers with your question. It saves us both a round of back and forth.

How these numbers are worked out
  • Solar array: daily use divided by sun hours, plus about 25 percent for wiring, heat, and inverter losses. Ohio averages about 4.5 peak sun hours a day over a year and about 2.3 in December (NREL PVWatts). The sizer plans on 4 for the year to leave room for clouds, or 2.3 when you check the winter box. Rounded up to whole 400 watt panels.
  • Battery bank: daily use times days of backup gives the usable energy you need. LiFePO4 is planned at 80 percent usable, so the total bank is a bit bigger.
  • Inverter: the most you run at once plus 25 percent headroom, rounded up to a common size. Motors like well pumps and compressors pull a big surge on startup, so tell us about those.
  • System voltage: 12 V for small setups, 24 V for mid size, and 48 V once the inverter gets past about 3,000 watts.

These are rough planning numbers. A real design checks your actual appliances, wire runs, and where the panels will sit.